Technique Note:
In the tibia, insert Schanz screws in the "safe corridor" for Schanz screw insertion described by
Behrens and Searls (5).
Illustration from the Manual of Internal Fixation, Third Edition
(5) Behrens, F. and K. Searls. "External Fixation of the Tibia." British Journal of Bone and Joint Surgery 68 (1986): 246-254.